0 Cookie Img

Insertion Flowmeter for Compressed Air and Gases

Insertion Flowmeter for Compressed Air and Gases
Insertion Flowmeter for Compressed Air and Gases
Product Code : EE776
Product Description

Our enterprise is an outstanding exporter and importer of a huge array of Insertion Flowmeter for Compressed Air and Gases. The flowmeter given by us is ideally used for the volumetric measurements of gases and liquids.  This meter is examined against diverse quality norms under the strict vigilance of experienced experts to ensure flawless supplies. For ensuring zero defects in products, insertion flowmeter for compressed air and gases undergo various quality evaluation stages conducted by our professionals on the set industry norms and standards.

Technical Data :

Measuring value


Flow


Measurand

Volumetric flow at standard conditions acc. DIN 1343 P0 = 1013.25 mbar (14.7 PSI); t0 = 0 oC (32 oF)

Measuring range

0.2...100 Nm/s (40...19685 SFPM) or 0.2...200 Nm/s (40...39370 SFPM)

Accuracy in air at 9bar (130.5psi) (abs) and 23oC (73oF)1)

+ (1.5% of measuring value + 0.8% of full scale)

Temperature coefficient

+ (0.1% of measuring value / oC)

Pressure coefficient 2)

+ 0.5% of measuring value / bar

Response time t90

< 1 sec.

Sample rate

0.5 sec.

Temperature


Measuring range

-20...80 oC (-4...176 oF)

Accuracy at 20oC (68oF)

+ 0.7 oC (1.26 °F)

Outputs


Output signal and display ranges are freely scalable Analogue output
voltage
current (3-wire)



0 - 10 V max. 1 mA
0 - 20 mA and 4 - 20 mA RL<500 Ohm

Switching output

potential-free max. 44 VDC, 500 mA switching capacity

Pulse output

Totalizer, pulse length: 0.02...2 sec.

Bus interface

MODBUS RTU or M-BUS (Meter-Bus)

Digital interface

USB (for configuration)

Input

Optional pressure compensation

4 - 20 mA (2-wire; 15 V) for pressure sensor

General

Supply voltage

18 - 30 V AC/DC

Current consumption

max. 200 mA

Temperature range

ambient temperature: -20...60 oC (-4...140 oF)
medium temperature: -20...80 oC (-4...176 oF)
storage temperature: -20...60 oC (-4...140 oF)

Humidity working range

0...99 %RH no condensation

max. working pressure

16 bar (232 Psi)

Medium

compressed air or Non-Corrosive gases

Electrical connection

cable gland M16x1.5 (optional connector M12x1 8pol.)

Electromagnetic compatibility

EN61326-1 EN61326-2-3 Industrial Environment

Material :
housing
probe
sensor head
non-return protection


metal (AlSi3Cu)
stainless steel
stainless steel / glass
brass

Housing protection class

IP65 / Nema 4

Contact Us

401 & G-414-416 A Wing, Kailash Indl. Complex, Near Dynalog, Behind Godrej Colony, Park Site, Vikhroli (West), Mumbai, Maharashtra, 400079, India