Digital 2-wire, Self-Contained IR thermometer with Precision Dual Laser targeting from -58 to 2912oF (-50 to 1600oC)

Features :

  • Fast, high accuracy and small spot size
  • Optical resolution up to 300:1 with selectable optics
  • Double laser aiming identifies real spot location and actual spot size at any distance
  • Scalable 4-20 mA output in combination with simultaneous alarm output
  • USB programming interface and software optional
  • On board emissivity adjustment or remote via software
  • Short circuit and polarity reversal protection
  • Usable up to 85oC ambient temperature without cooling
  • Automatic laser switch off at 50oC
  • Wide power requirement range: 5 to 28 V DC

General specifications :

Environmental rating

IP 65 (NEMA-4)

Ambient temperature

-20 - 85°C (50°C with laser on)

Storage temperature

-40 - 85°C

Relative humidity

10 - 95 %, non condensing

Vibration

IEC 68-2-6: 3 G, 11-200 Hz, any axis

Shock

IEC 68-2-27: 50 G, 11 ms, any axis

Weight

600 g

Electrical specifications

Output/analog

4 - 20 mA1

Loop resistance

max. 1000

Output/ alarm

0-30 V/ 500mA (open collector)

Output/ digital

uni-/ bidirectional, 9.6 kBaud, 0/3 V digital level, USB optional

Cable length (connector version only)

3 m/ 8 m/ 15 m

Current draw (laser)

45mA @ 5V, 20mA @ 12V, 12mA @ 24V

Power supply

5 - 28 V DC

Measurement specifications :

Temperature range (scalable via software)

(LT) -58 to 1787oF/-50 to 975oC (2MH) 725 to 2912oF/385 to 1600oC

Spectral range / model

8 - 14 µm / PSC-CS Laser-LT 1.6 µm / PSC-CS Laser-2MH

Optical resolution

50:1 (LT) 300:1 (2MH)

System accuracy LT (at ambient temperature 23 +5oC)

+ 1% or + 1oC1)

System accuracy 2MH (at ambient temperature 23 +5oC)

+(0.3% of reading +2oC) 2)

Repeatability LT (at ambient temperature 23 +5oC)

+ 0.5% or +0.5oC 1)

Repeatability 2MH (at ambient temperature 23 +5oC)

+(0.1% of reading +1oC) 2)

Temperature resolution (digital)

0.1 K

Response time (90% signal)

150 ms (LT) 10 ms (2MH)

Emissivity/ Gain (adjustable via switches or via software)

0.100 - 1.100

IR window correction (adjustable via software)

0.100 - 1.000

Signal processing (parameter adjustable via software)

peak hold, valley hold, average; extended hold function with threshold and hysteresis