JUPITER INTEGRATED SENSOR SYSTEMS PVT. LTD.
The OEM Transmitter

The OEM Transmitter

Send Inquiry

In this industry, our name is renowned as one of the prominent exporters and importers of The OEM Transmitter which is used for hydraulics and pneumatics pumps and building services and compressors machine. A large array of electrical and process connections as well as all ideally used pressure ranges and output signals set the model O-10 apart. The offered transmitter is available in various specifications in accordance with the consumer’s demands. To ensure the satisfaction of our customers, we are able to deliver this the OEM transmitter in perfect order.

Service-Interface :

  • UART (Mini-USB)

Board :

  • Compact size
  • Easy to install

Outputs :

  • Two freely scalable analog outputs
  • Available as 2-wire (XB20) or 3/4-wire (XB3x)
  • UART service-interface

Pt100 RTD output :

  • Direct 4-wire connection optional available

Wide selection of probes :

  • PPS and steel probes with a temperature range up to
  • 200oC available (With Hygromer HH-1R sensor up to 180 oC)
  • 15mm and 25/15mm probe diameter available
  • Probe lengths up to 700 mm

AirChip3000 :

  • Compensates humidity and temperature over 30,000 reference points
  • 2,000 data point memory
  • Dew/frost point calculation
  • Sensor auto-diagnostics and automatic correction
  • Active alarming and information
  • ASIC (Application Specific Integrated Circuit), micro-controller and EEPROM on one chip

Technical Specification :

Specification

XB20

XB3

Power supply / Connections

Circuit type

2-wire loop powered

3-wire

Supply voltage VDC

10…28 VDC , V min = 10 V + (0.02 x Load)
Load resistance in ohms

15…40 VDC or 12…28 VAC

Output signal type

4...20 mA

0...1V, 0...5V, 0...10V,
0...20 mA, 4...20 mA

Nominal current consumption

2 x 20 mA

< 50 mA

Electrical connections

Terminal block

Polarity protection

Protective diode on V+

Humidity measurement

Sensor

Hygromer® IN-1

Measurement range

0…100 %rh

Measurement accuracy at 23 oC

+1.0 %rh

Repeatability

0.3 %rh

Long term stability

< 1 %rh / year

Temperature measurement

Sensor (Standard)

Pt100 RTD, IEC 751 1/3 class B

Measuring range

-100…200oC (see also environmental limits)

Measurement accuracy at 23 oC

+0.2oC

Repeatability

0.05 oC

Long term stability

< 0.1 oC / year

Calculated parameters

Psychrometric calculations

Dew or frost point (user configurable option)

Environmental limits

Storage and transit

-50…+70 oC, 0…100 %rh, non condensing

Operating limits at electronics

-40… +85 oC, 0…100 %rh, non condensing

Maxi. humidity /temperature at sensor

See humidity/temperature window of sensor

Maximum air velocity at probe

40 m/s (7,870 ft /min) - depends on dust filter type

Digital interface (service connector)

Interface type

UART (Universal Asynchronous Receiver Transmitter)

Maximum service cable length

5 m (16.4 ft)

Firmware update

Via service connector, requires HW4 software

Start-up time and data refresh rate

Start-up time

3.4s (typical)

1.9s (typical)

Data refresh rate

3.4s (typical)

1.7s (typical)

Conformity with standards

CE / EMC immunity

EMC Directive 2004/108/EG:
EN 61000-6-1: 2001 EN 61000-6-2: 2005
EN 61000-6-3: 2005, EN 61000-6-4: 2001 + A11

Solder type

Lead free (RoHS directive)

FDA / GAMP directives

Compatible