Transportable RH and Temperature Calibration Laboratory

Transportable RH and Temperature Calibration Laboratory
Transportable RH and Temperature Calibration Laboratory
Product Code : PSC PTLST-20-1M-2M
Product Description

Salient Features :

  • Temperature ranges from 725 3252oF (385 1800oC)
  • High optical resolution up to 300:1
  • Precise aiming with dual laser and scope sighting
  • Adjustable emissivity from 0.100 1.000
  • Short wavelength spectral responses minimizes temperature errors due to changes in product emissivitys
  • MAX/MIN function and audible and visible HIGH-/LOW-alarm
  • USB interface, PSC Connect RSoftware
  • Data logger for 2000 measured values

Specification :

General specifications

Ambient temperature

32 - 122oF (0 - 50oC)

Storage Temperature

- 4 - 140oF (-20 - 60oC)

Relative Humidity

10 - 95%, non-condensing

Size

10.3 x 8 x 2.36 in/264 x 203.5 x 60 mm

Weight

2.2 lbs/1000 g

Electrical specifications

Outputs/digital

USB Interface

Power

Ni-MH rechargeable battery

Battery Life Time

5 hr laser and backlight or 25 hr w/o laser and backlight

Charge

Battery charger

Adapter

110VAC to 240VAC (50/60Hz)

Measurement specifications

Temperature ranges

1202 - 3272oF/650 - 1800oC (1M)
725 - 2912oF/385 - 1600oC (2M)

Optical resolution-1M/2M

300:1

System accuracy-1M/2M

+0.3% of reading +1oC

Repeatability-1M/2M

+0.1% of reading +1oC

Response time-1M/2M

100 ms

Emissivity (adjustable)

0.100 - 1.000

Sighting-1M/2M

Dual lasers

Sighting scope

All models

Signal processing

MAX/MIN, Scan/Hold function

Alarm functions

Audible and visible HIGH/LOW

Data storage

2000 values

LCD-Backlight

Three color alarm notification
Green - normal operation
Blue - low set point
Red - high set point


Salient Features :

  • Temperature ranges from 725 3252oF (385 1800oC)
  • High optical resolution up to 300:1
  • Precise aiming with dual laser and scope sighting
  • Adjustable emissivity from 0.100 1.000
  • Short wavelength spectral responses minimizes temperature errors due to changes in product emissivitys
  • MAX/MIN function and audible and visible HIGH-/LOW-alarm
  • USB interface, PSC Connect RSoftware
  • Data logger for 2000 measured values

Specification :

General specifications

Ambient temperature

32 - 122oF (0 - 50oC)

Storage Temperature

- 4 - 140oF (-20 - 60oC)

Relative Humidity

10 - 95%, non-condensing

Size

10.3 x 8 x 2.36 in/264 x 203.5 x 60 mm

Weight

2.2 lbs/1000 g

Electrical specifications

Outputs/digital

USB Interface

Power

Ni-MH rechargeable battery

Battery Life Time

5 hr laser and backlight or 25 hr w/o laser and backlight

Charge

Battery charger

Adapter

110VAC to 240VAC (50/60Hz)

Measurement specifications

Temperature ranges

1202 - 3272oF/650 - 1800oC (1M)
725 - 2912oF/385 - 1600oC (2M)

Optical resolution-1M/2M

300:1

System accuracy-1M/2M

+0.3% of reading +1oC

Repeatability-1M/2M

+0.1% of reading +1oC

Response time-1M/2M

100 ms

Emissivity (adjustable)

0.100 - 1.000

Sighting-1M/2M

Dual lasers

Sighting scope

All models

Signal processing

MAX/MIN, Scan/Hold function

Alarm functions

Audible and visible HIGH/LOW

Data storage

2000 values

LCD-Backlight

Three color alarm notification
Green - normal operation
Blue - low set point
Red - high set point


Contact Us

401 & G-414-416 A Wing, Kailash Indl. Complex, Near Dynalog, Behind Godrej Colony, Park Site, Vikhroli (West), Mumbai, Maharashtra, 400079, India